Magnetic Level Indicator

For Bi-colour Type (Side Mounted) Model No. : MI - 03

INTRODUCTION
The By-Pass Level Indicator installed outside of a vessel or tank. The liquid level in the tank can easily be observed from the change of the flag color. Optional devices of magnetic switch and level transducer can be added for electrical signal output and level transmitting.

PRINCIPLE
The By-Pass indicator utilizes hydrostatic principle to show the liquid level in the tank. A float with a magnet inside rises and drops according to the liquid level change. Magnetic flags will flip as float passes through to indicate liquid level based on magnetic attraction method.

Specification
Connection Flanged ASA 150 R F
Range 300 mm TO 6000 mm
Press Rating 25 Kg/cm2
Temp. Rating 150 ºC
Calibration cms / mm / Inches
Material of Wetted Parts S.S. 304 / S.S. 316 /P.P.
General Data
Density From 0.70 g/cm 3
Precision for interface or density From + 0.01 g/cm 3
Measuring Error +10mm
Viscosity Max 1000mPas
Connection Flanges DIN and ANSI
Weight Basic 7 Kg
Design Data
Mounting Top or Side
Operating Pressure Up to 50 Kg/cm2
Operating Temperature -20 °C to 400 °C
Process Connection Flanged or Screwed
C-C Distance (±3 mm) Up to 6000mm
Flaf Display Length Up to 6000mm
Specific Gravity 0.75 (Min.)
Indicator Roller Metallic

Magnetic Level Indicator

for Red Follower (Side Mounted) Model No. : MI - 02

INTRODUCTION
The By-Pass Level Indicator installed outside of a vessel or tank. The liquid level in the tank can easily be observed from the change of the flag color. Optional devices of magnetic switch and level transducer can be added for electrical signal output and level transmitting.

PRINCIPLE
The By-Pass indicator utilizes hydrostatic principle to show the liquid level in the tank. A float with a magnet inside rises and drops according to the liquid level change. Magnetic flags will flip as float passes through to indicate liquid level based on magnetic attraction method.

Specification
Connection Flanged ASA 150 R F
Range 300 mm TO 6000 mm
Press Rating 25 Kg/cm2
Temp. Rating 150 ºC
Calibration cms / mm / Inches
Material of Wetted Parts S.S. 304 / S.S. 316 /P.P.
General Data
Density From 0.70 g/cm 3
Precision for interface or density From + 0.01 g/cm 3
Measuring Error +10mm
Viscosity Max 1000mPas
Connection Flanges DIN and ANSI
Weight Basic 7 Kg
Design Data
Mounting Top or Side
Operating Pressure Up to 50 Kg/cm2
Operating Temperature -20 °C to 400 °C
Process Connection Flanged or Screwed
C-C Distance (±3 mm) Up to 6000mm
Flaf Display Length Up to 6000mm
Specific Gravity 0.75 (Min.)
Indicator Roller Metallic

Optional Accessories
Magnetic Level Switches
Reed switches or electrical snap (magnetic pendulum switch) may be mounted on the rail of the level gauge to be
activated at high / low levels. The numbe rof switches is only limited by length of the indication rail and the switches can be mounted on the left and right side of the rail. Mounting the level switches is a very easy task.

Magnetic Level Transmitter
The analogue transmitter mounts directly to the side of the level gauge chamber, providing a continuous 4-20mA output signal propotional to the liquid level with an accuracy of +3mm. Using simple and reliable reed switches surface mounted to a printed circuit board. The transmitter can be equipped with a local indicator to show the level height in a length scale or indicate the percentage of the total height or the tank volume.

Magnetic Level Indicator

(Top Mounting) Model No. : MI - 03

INTRODUCTION
The By-Pass Level Indicator is installed outside of a vessel or tank. The liquid level in the tank can easily be observed from the change of the flag color.Optional devices of magnetic switch and level transducer can be added for electrical signal output and level transmitting.

PRINCIPLE
The By-Pass indicator utilizes hydrostatic principle to show the liquid level in the tank. A float with a magnet inside rises and drops according to the liquid level change. Magnetic flags will flip as float passes through to indicate liquid level based on magnetic attraction method.

General Data
Density From 0.70 g/cm 3
Precision for interface or density From ±0.01 g/cm 3
Measuring Error ±10mm
Viscosity Max 1000mPas
Connection Weld End (Standard) / Flanges DIN and ANSI
Weight Basic 7 Kg
Design Data
Mounting Top or Side
Operating Pressure Up to 50 Kg/cm2
Operating Temperature -20 °C to 400 °C
Process Connection Flanged or Screwed
C-C Distance (±3 mm) Up to 6000mm
Flaf Display Length Up to 6000mm
Specific Gravity 0.75 (Min.)
Indicator Roller Metallic

Magnetic Level Indicator

(Top Mounting) Model No. : MI - 04

INTRODUCTION
The By-Pass Level Indicator is installed outside of a vessel or tank. The liquid level in the tank can easily be observed from the change of the flag color.Optional devices of magnetic switch and level transducer can be added for electrical signal output and level transmitting.

PRINCIPLE
The By-Pass indicator utilizes hydrostatic principle to show the liquid level in the tank. A float with a magnet inside rises and drops according to the liquid level change. Magnetic flags will flip as float passes through to indicate liquid level based on magnetic attraction method.

General Data
Density From 0.70 g/cm 3
Precision for interface or density From ±0.01 g/cm 3
Measuring Error ±10mm
Viscosity Max 1000mPas
Connection Weld End (Standard) / Flanges DIN and ANSI
Weight Basic 7 Kg
Design Data
Mounting Top or Side
Operating Pressure Up to 50 Kg/cm2
Operating Temperature -20 °C to 400 °C
Process Connection Flanged or Screwed
C-C Distance (±3 mm) Up to 6000mm
Flaf Display Length Up to 6000mm
Specific Gravity 0.75 (Min.)
Indicator Roller Metallic